Continuous Emission Monitoring Systems
Continuous Water Monitoring Systems
- BOD ANALYZER
- ONLINE COD
- ONLINE TOTAL ORGANIC CARBON (TOC)
- SILICON DIOXIDE ANALYZER
- TOXICITY ANALYZER
- AMMONIA NITROGEN ANALYZER
- DEGASSING ACID CONDUCTIVITY
- SODIUM ANALYZER
- CHLORINE ANALYZER
- DISSOLVED OXYGEN ANALYZER
- ONLINE WATER QUALITY MONITORING
- ONLINE HEAVY MENTAL MONITORING
- TURBIDIMETER
- ONLINE PH METER
- Technical Exchange Platform
Airborne Molecular Contamination Monitoring
Environmental Monitoring and Industrial Safety
Particle Monitoring Systems
Gas Analyzers
- CO2/CO/N2O ANALYZER
- NO/SO2/CO2/CO/CH4/CH2O/NH3 ANALYZER
- NO/NO2/NOX ANALYZER
- TRACE MOISTURE ANALYZER
- TRACE NITROGEN ANALYZER
- GAS CHROMATOGRAPH
- OXYGEN ANALYZER
- TOTAL HYDRO CARBON ANALYZER
- Technical Exchange Platform
- NIR PHOTOMETERS
- SULFUR GAS ANALYZERS
- ULTRAVIOLET PHOTOMETRIC ANALYZER
- F2/CL2 ANALYZER
- GAS DILUTION SYSTEM
- HIGH PURITY GAS STREAM SELECTOR
Emissions / Air Flow Sensor
OSI OFS-2000F
Features
- Specifically designed for Flares stack and reports flow velocities from 0.03 - 170 m/sec with a ± 2% accuracy.
- Accurate flow readings.
- Easy installation and optical alignment.
- Long-term reliability: no blowers or moving parts
- Ultra-low maintenance design.
- Rugged; designed for harsh environments.
- Built in continuous self-test diagnostics.
- Measurement unaffected by path length & media pressure, moisture & opacity.
- No flow media high temperature limits.
- Compliant with EPA 40CFR Parts 60 & 75.
Specifications
- Measurement Technique: Optical Scintillation (OSi Patented)
- Range: 0.03 to 100 m/sec, bidirectional (higher rates possible on RS-232 port)
- Accuracy (Absolute): ±0.1 m/sec basic -or- ±2% of reading, whichever is greater
- Repeatability (Relative): ± 1% of reading
- Long Term Drift: Less than 1% per decade
- Response Time: Response 0.3 sec., Update: 3 sec., Averaging (selectable): 3-600 sec.