Multi-component Gas Analyzer

DR. FODISCH MCA10

Features

  • TUV and US EPA tests and met local environmental regulations
  • Simultaneous measurement of 12 component gases
  • Analysis components: SO2, NO, NO2, CO, HCL, NH3, CO2, O2, H2O, CH4
  • For waste incineration plants, cement plants, power plants, chemical plants, etc.
  • CEMS Continuous Monitoring System

Specifications

  • Measurement range: SO2: 0 ~ 2,500mg / m3, NO: 0 ~ 3,000mg / m3, NO2: 0 ~ 500mg / m3, CO: 0 ~ 5,000mg / m3, HCL: 0 ~ 5,000mg / m3, NH3 : 0 ~ 500mg / m3, CO2: 0 ~ 50%, O2: 0 ~ 25%, N2O :: 0 ~ 3,000mg / m3, H2O: 0 ~ 40%, CH4: 0 ~ 500mg / m3
  • Accuracy: <2% of full-scale
  • Response time: 10 sec
  • Operating temperature: 5 ~ 40 ℃
  • Path length of measuring unit: 2 ~ 10m
  • Signal output: 4 ~ 20mA