Continuous Emission Monitoring Systems
Continuous Water Monitoring Systems
- BOD ANALYZER
- ONLINE COD
- ONLINE TOTAL ORGANIC CARBON (TOC)
- SILICON DIOXIDE ANALYZER
- TOXICITY ANALYZER
- AMMONIA NITROGEN ANALYZER
- DEGASSING ACID CONDUCTIVITY
- SODIUM ANALYZER
- CHLORINE ANALYZER
- DISSOLVED OXYGEN ANALYZER
- ONLINE WATER QUALITY MONITORING
- ONLINE HEAVY MENTAL MONITORING
- TURBIDIMETER
- ONLINE PH METER
- Technical Exchange Platform
Airborne Molecular Contamination Monitoring
Environmental Monitoring and Industrial Safety
Particle Monitoring Systems
Gas Analyzers
- CO2/CO/N2O ANALYZER
- NO/SO2/CO2/CO/CH4/CH2O/NH3 ANALYZER
- NO/NO2/NOX ANALYZER
- TRACE MOISTURE ANALYZER
- TRACE NITROGEN ANALYZER
- GAS CHROMATOGRAPH
- OXYGEN ANALYZER
- TOTAL HYDRO CARBON ANALYZER
- Technical Exchange Platform
- NIR PHOTOMETERS
- SULFUR GAS ANALYZERS
- ULTRAVIOLET PHOTOMETRIC ANALYZER
- F2/CL2 ANALYZER
- GAS DILUTION SYSTEM
- HIGH PURITY GAS STREAM SELECTOR
Opacity/Dust Monitor
CODEL DCEM 2100
Features
- % opacity or dust density in mg/Nm3
- Low certified range 0 - 0.1 Ext
- Dual-pass, open-path transmissometer
- Integral auto zero and span check
- Dynamic misalignment check
- Full contamination check on all active optical surfaces
- Integral high efficiency air curtains for maximum uninterrupted service
Specifications
- Operating Principle Dual-pass transmissometer
- Optical Path Length 0.5 to 15m, longer path lengths available on request
- Accuracy +/- 0.2% opacity
- Response Time 10 Seconds
- Certified Range 0 to 0.1 Ext (0 - 20% opacity or 0 - 10 mg/m3 at 5m)
- Resolution 0.1% opacity
- Drift <1% opacity per month